{"id":475983,"date":"2023-08-09T07:25:33","date_gmt":"2023-08-09T07:25:33","guid":{"rendered":""},"modified":"2023-09-05T11:11:47","modified_gmt":"2023-09-05T11:11:47","slug":"baseboard-management-controller","status":"publish","type":"wiki","link":"https:\/\/oneproxy.pro\/tr\/wiki\/baseboard-management-controller\/","title":{"rendered":"Anakart y\u00f6netim denetleyicisi"},"content":{"rendered":"<h2>girii\u015f<\/h2>\n<p>Temel Kart Y\u00f6netim Denetleyicisi (BMC), modern bilgisayar sistemlerinde \u00e7e\u015fitli donan\u0131mlar\u0131n y\u00f6netilmesinden ve sistem sa\u011fl\u0131\u011f\u0131n\u0131n izlenmesinden sorumlu \u00e7ok \u00f6nemli bir bile\u015fendir. Anakart \u00fczerinde \u00f6zerk bir alt sistem g\u00f6revi g\u00f6r\u00fcr ve ana i\u015flemci kapal\u0131yken veya yan\u0131t vermedi\u011finde bile uzaktan y\u00f6netim ve izleme \u00f6zelliklerini kolayla\u015ft\u0131r\u0131r. BMC, uzaktan g\u00fc\u00e7 kontrol\u00fc, sistem izleme ve sistem konsoluna bant d\u0131\u015f\u0131 eri\u015fim gibi temel i\u015flevleri sa\u011flar. Bu makale BMC&#039;nin ge\u00e7mi\u015fi, yap\u0131s\u0131, \u00f6zellikleri, t\u00fcrleri, kullan\u0131m durumlar\u0131 ve OneProxy gibi proxy sunucu sa\u011flay\u0131c\u0131lar\u0131yla ili\u015fkisi hakk\u0131nda ayr\u0131nt\u0131l\u0131 bilgi sa\u011flamay\u0131 ama\u00e7lamaktad\u0131r.<\/p>\n<h2>Tarih ve \u0130lk S\u00f6z<\/h2>\n<p>BMC kavram\u0131n\u0131n k\u00f6keni, sistem y\u00f6neticilerinin bilgisayar sistemlerini uzaktan y\u00f6netmenin yollar\u0131n\u0131 arad\u0131\u011f\u0131 1990&#039;lar\u0131n ba\u015flar\u0131na kadar uzanabilir. BMC benzeri i\u015flevlerden ilk kez 1998 y\u0131l\u0131nda Intel, Dell, Hewlett-Packard ve NEC taraf\u0131ndan tan\u0131t\u0131lan Ak\u0131ll\u0131 Platform Y\u00f6netim Aray\u00fcz\u00fc (IPMI) spesifikasyonunda bahsedilmi\u015ftir. IPMI, sistem y\u00f6neticilerinin sistem sa\u011fl\u0131\u011f\u0131n\u0131 izlemesine ve donan\u0131m bile\u015fenlerini ana i\u015fletim sisteminden ba\u011f\u0131ms\u0131z olarak y\u00f6netmesine olanak tan\u0131yan donan\u0131m d\u00fczeyinde aray\u00fcz spesifikasyonlar\u0131 i\u00e7in bir standart belirledi.<\/p>\n<h2>Anakart Y\u00f6netim Kontrol\u00f6r\u00fc Hakk\u0131nda Detayl\u0131 Bilgi<\/h2>\n<p>Anakart Y\u00f6netim Denetleyicisi ana CPU&#039;dan ba\u011f\u0131ms\u0131z olarak \u00e7al\u0131\u015f\u0131r ve kendine ait i\u015flemciye, belle\u011fe ve a\u011f aray\u00fcz\u00fcne sahiptir. Tipik olarak, sistemi y\u00f6netmek i\u00e7in \u00f6zel olarak tasarlanm\u0131\u015f \u00fcr\u00fcn yaz\u0131l\u0131m\u0131na sahip bir mikro denetleyici veya d\u00fc\u015f\u00fck g\u00fc\u00e7l\u00fc bir CPU kullan\u0131r. BMC&#039;ye Ak\u0131ll\u0131 Platform Y\u00f6netim Veriyolu (IPMB), LAN \u00fczerinden Seri (SOL) gibi \u00e7e\u015fitli ileti\u015fim kanallar\u0131 veya Ethernet gibi \u00f6zel a\u011f aray\u00fczleri arac\u0131l\u0131\u011f\u0131yla eri\u015filebilir.<\/p>\n<h2>\u0130\u00e7 Yap\u0131 ve \u0130\u015fleyi\u015f<\/h2>\n<p>BMC&#039;nin i\u00e7 yap\u0131s\u0131 a\u015fa\u011f\u0131daki temel bile\u015fenlerden olu\u015fur:<\/p>\n<ol>\n<li><strong>Mikrodenetleyici\/CPU<\/strong>: Bu, BMC&#039;nin beyni olarak g\u00f6rev yapar ve i\u015flevlerinden sorumlu ayg\u0131t yaz\u0131l\u0131m\u0131n\u0131 y\u00fcr\u00fct\u00fcr.<\/li>\n<li><strong>Firmware<\/strong>: \u00dcr\u00fcn yaz\u0131l\u0131m\u0131, mikro denetleyici \u00fczerinde \u00e7al\u0131\u015fan ve BMC&#039;nin sistem olaylar\u0131n\u0131 y\u00f6netme ve y\u00f6netim komutlar\u0131na yan\u0131t verme gibi g\u00f6revlerini ger\u00e7ekle\u015ftirmesini sa\u011flayan \u00f6zel bir yaz\u0131l\u0131m program\u0131d\u0131r.<\/li>\n<li><strong>Sistem Sens\u00f6rleri<\/strong>: BMC, s\u0131cakl\u0131k, voltaj, fan h\u0131z\u0131 ve di\u011fer hayati parametreleri takip etmek i\u00e7in sens\u00f6rleri kullanarak sistemin sa\u011fl\u0131\u011f\u0131n\u0131 s\u00fcrekli olarak izler.<\/li>\n<li><strong>Sistem Olay G\u00fcnl\u00fc\u011f\u00fc<\/strong>: BMC, kritik sistem olaylar\u0131n\u0131n bir kayd\u0131n\u0131 tutar ve y\u00f6neticilerin te\u015fhis amac\u0131yla ge\u00e7mi\u015f olaylar\u0131 analiz etmesine olanak tan\u0131r.<\/li>\n<li><strong>A\u011f Aray\u00fcz\u00fc<\/strong>: BMC, bant d\u0131\u015f\u0131 ileti\u015fimi kolayla\u015ft\u0131rmak i\u00e7in, ana sistem yan\u0131t vermese bile uzaktan eri\u015fime ve kontrole olanak tan\u0131yan \u00f6zel bir a\u011f aray\u00fcz\u00fcne sahiptir.<\/li>\n<li><strong>Uzaktan Konsol Eri\u015fimi<\/strong>: BMC, uzaktan konsol eri\u015fimi sa\u011flayarak y\u00f6neticilerin sistem durumunu g\u00f6r\u00fcnt\u00fclemesine ve Seri LAN (SOL) veya benzer aray\u00fczler arac\u0131l\u0131\u011f\u0131yla sistemle etkile\u015fime girmesine olanak tan\u0131r.<\/li>\n<\/ol>\n<h2>S\u00fcp\u00fcrgelik Y\u00f6netim Denetleyicisinin Temel \u00d6zellikleri<\/h2>\n<p>BMC, sunucu y\u00f6netilebilirli\u011fini ve g\u00fcvenilirli\u011fini art\u0131ran \u00e7e\u015fitli temel \u00f6zelliklere sahiptir:<\/p>\n<ol>\n<li><strong>Uzaktan G\u00fc\u00e7 Kontrol\u00fc<\/strong>: BMC, sunucu \u00fczerinde uzaktan a\u00e7ma, kapatma ve kapatma i\u015flemlerine izin vererek y\u00f6neticilerin internet ba\u011flant\u0131s\u0131 olan her yerden bak\u0131m yapmas\u0131na veya sorunlar\u0131 \u00e7\u00f6zmesine olanak tan\u0131r.<\/li>\n<li><strong>Uyar\u0131 ve \u0130zleme<\/strong>: BMC, sistem sa\u011fl\u0131\u011f\u0131n\u0131 s\u00fcrekli olarak izler ve potansiyel sorunlar\u0131 veya kritik olaylar\u0131 tespit etti\u011finde y\u00f6neticilere uyar\u0131 g\u00f6ndererek proaktif y\u00f6netime olanak tan\u0131r.<\/li>\n<li><strong>Sistem kurtarma<\/strong>: Kritik ar\u0131za veya sistem \u00e7\u00f6kmesi durumunda BMC, sistem kurtarma prosed\u00fcrlerini ba\u015flatarak ar\u0131za s\u00fcresini azaltabilir ve sistem kullan\u0131labilirli\u011fini iyile\u015ftirebilir.<\/li>\n<li><strong>BIOS Y\u00f6netimi<\/strong>: BMC, sistem BIOS&#039;una uzaktan eri\u015fime ve yap\u0131land\u0131rmaya izin vererek \u00fcr\u00fcn yaz\u0131l\u0131m\u0131 g\u00fcncellemelerini ve yap\u0131land\u0131rma de\u011fi\u015fikliklerini basitle\u015ftirir.<\/li>\n<li><strong>Sanal Medya Deste\u011fi<\/strong>: Y\u00f6neticiler uzak g\u00f6r\u00fcnt\u00fcleri sunucuya sanal ortam olarak ba\u011flamak i\u00e7in BMC&#039;yi kullanabilir, b\u00f6ylece uzaktan i\u015fletim sistemi kurulumlar\u0131na ve kurtarma i\u015flemlerine olanak sa\u011flan\u0131r.<\/li>\n<\/ol>\n<h2>Anakart Y\u00f6netim Denetleyicisi T\u00fcrleri<\/h2>\n<p>BMC \u00e7\u00f6z\u00fcmleri, \u00fcreticiye ve sistem mimarisine ba\u011fl\u0131 olarak farkl\u0131 varyantlara sahiptir. Ana t\u00fcrler \u015funlar\u0131 i\u00e7erir:<\/p>\n<table>\n<thead>\n<tr>\n<th>Tip<\/th>\n<th>Tan\u0131m<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>\u00d6zel BMC<\/strong><\/td>\n<td>Sunucu donan\u0131m\u0131na entegre edilmi\u015f ba\u011f\u0131ms\u0131z bir BMC<\/td>\n<\/tr>\n<tr>\n<td><strong>Entegre BMC<\/strong><\/td>\n<td>BMC i\u015flevselli\u011fi sunucunun ana kart\u0131na entegre edilmi\u015ftir<\/td>\n<\/tr>\n<tr>\n<td><strong>SoC BMC<\/strong><\/td>\n<td>BMC, sunucunun \u00c7ip \u00dczerindeki Sistemine (SoC) entegre edildi<\/td>\n<\/tr>\n<tr>\n<td><strong>Harici BMC<\/strong><\/td>\n<td>USB veya LAN arac\u0131l\u0131\u011f\u0131yla ba\u011flanan ayr\u0131 bir BMC cihaz\u0131<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>BMC&#039;yi Kullanma Yollar\u0131 ve Yayg\u0131n Sorunlar<\/h2>\n<p>Anakart Y\u00f6netim Denetleyicileri a\u015fa\u011f\u0131dakiler de dahil olmak \u00fczere \u00e7e\u015fitli senaryolarda uygulama alan\u0131 bulur:<\/p>\n<ul>\n<li><strong>Uzak Sunucu Y\u00f6netimi<\/strong>: Y\u00f6neticiler uzak veri merkezlerinde veya uzak sitelerde bulunan sunucular\u0131 verimli bir \u015fekilde y\u00f6netebilir.<\/li>\n<li><strong>Sorun Giderme ve Te\u015fhis<\/strong>: BMC, donan\u0131m ar\u0131zalar\u0131n\u0131n ve sistem hatalar\u0131n\u0131n belirlenmesine yard\u0131mc\u0131 olarak h\u0131zl\u0131 sorun giderme ve \u00e7\u00f6z\u00fcme olanak tan\u0131r.<\/li>\n<li><strong>G\u00fc\u00e7 Optimizasyonu<\/strong>: BMC, g\u00fc\u00e7 izleme ve y\u00f6netimini kolayla\u015ft\u0131rarak enerji verimli operasyonlara katk\u0131da bulunur.<\/li>\n<\/ul>\n<p>Ancak her teknoloji gibi BMC de a\u015fa\u011f\u0131dakiler dahil sorunlarla kar\u015f\u0131la\u015fabilir:<\/p>\n<ul>\n<li><strong>G\u00fcvenlik endi\u015feleri<\/strong>: Uygun \u015fekilde g\u00fcvenli hale getirilmeyen BMC aray\u00fczleri, sald\u0131rganlar i\u00e7in potansiyel giri\u015f noktalar\u0131 haline gelebilir.<\/li>\n<li><strong>Uyumluluk ve Entegrasyon<\/strong>: Farkl\u0131 donan\u0131m sat\u0131c\u0131lar\u0131 ve sistem mimarileriyle uyumlulu\u011fun sa\u011flanmas\u0131 zor olabilir.<\/li>\n<\/ul>\n<p>Bu sorunlar\u0131 \u00e7\u00f6zmek i\u00e7in y\u00f6neticilerin BMC aray\u00fczlerini korumaya y\u00f6nelik en iyi uygulamalar\u0131 izlemesi ve d\u00fczenli \u00fcr\u00fcn yaz\u0131l\u0131m\u0131 g\u00fcncellemeleri yapmas\u0131 gerekir.<\/p>\n<h2>Ana \u00d6zellikler ve Kar\u015f\u0131la\u015ft\u0131rmalar<\/h2>\n<p>Baseboard Management Controller&#039;lar\u0131 benzer teknolojilerle kar\u015f\u0131la\u015ft\u0131ral\u0131m:<\/p>\n<p><strong>IPMI ve BMC<\/strong>: IPMI, BMC uygulamalar\u0131 i\u00e7in aray\u00fcz\u00fc tan\u0131mlayan spesifikasyondur. Bu nedenle, BMC ve IPMI yak\u0131ndan ili\u015fkilidir ve IPMI, BMC&#039;nin uydu\u011fu standartt\u0131r.<\/p>\n<table>\n<thead>\n<tr>\n<th>Bak\u0131\u015f a\u00e7\u0131s\u0131<\/th>\n<th>Anakart Y\u00f6netim Denetleyicisi (BMC)<\/th>\n<th>Ak\u0131ll\u0131 Platform Y\u00f6netim Aray\u00fcz\u00fc (IPMI)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Tan\u0131m<\/strong><\/td>\n<td>Uzaktan y\u00f6netim i\u00e7in donan\u0131m ve \u00fcr\u00fcn yaz\u0131l\u0131m\u0131 alt sistemi<\/td>\n<td>BMC&#039;yi y\u00f6netmek i\u00e7in standartla\u015ft\u0131r\u0131lm\u0131\u015f aray\u00fcz<\/td>\n<\/tr>\n<tr>\n<td><strong>\u0130\u015flevsellik<\/strong><\/td>\n<td>Uzaktan y\u00f6netim, izleme ve kontrol\u00fc y\u00f6netir<\/td>\n<td>BMC y\u00f6netimi i\u00e7in protokolleri ve komutlar\u0131 belirtir<\/td>\n<\/tr>\n<tr>\n<td><strong>Uygulama<\/strong><\/td>\n<td>Anakart \u00fczerinde fiziksel bir bile\u015fen olarak bulunur<\/td>\n<td>Firmware aray\u00fcz spesifikasyonu olarak uyguland\u0131<\/td>\n<\/tr>\n<tr>\n<td><strong>Kapsam<\/strong><\/td>\n<td>CPU ve bellenim i\u00e7eren t\u00fcm alt sistemi ifade eder<\/td>\n<td>Standartla\u015ft\u0131r\u0131lm\u0131\u015f ileti\u015fim aray\u00fcz\u00fcn\u00fc ifade eder<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Perspektifler ve Gelece\u011fin Teknolojileri<\/h2>\n<p>BMC&#039;nin gelece\u011fi geli\u015fmi\u015f g\u00fcvenlikte, bulut tabanl\u0131 y\u00f6netim platformlar\u0131yla daha geni\u015f entegrasyonda ve proaktif sistem y\u00f6netimi i\u00e7in daha geli\u015fmi\u015f yapay zeka odakl\u0131 tahmine dayal\u0131 analitiklerde yatmaktad\u0131r. Teknoloji geli\u015ftik\u00e7e BMC&#039;nin daha karma\u015f\u0131k hale gelmesi ve yeni nesil sunucu mimarileriyle daha iyi performans ve kusursuz entegrasyon sunmas\u0131 muhtemeldir.<\/p>\n<h2>Proxy Sunucular\u0131 ve Anakart Y\u00f6netim Denetleyicisi<\/h2>\n<p>OneProxy gibi proxy sunucu sa\u011flay\u0131c\u0131lar\u0131, sunucu altyap\u0131lar\u0131 i\u00e7in uzaktan y\u00f6netim yeteneklerini kullanarak BMC&#039;den yararlanabilirler. BMC, proxy sunucu sa\u011flay\u0131c\u0131lar\u0131n\u0131n sorunlar\u0131 an\u0131nda ele almas\u0131na, kesinti s\u00fcresini azaltmas\u0131na ve g\u00fc\u00e7 t\u00fcketimini optimize etmesine olanak tan\u0131yarak etkili izleme ve kontrol sa\u011flar.<\/p>\n<h2>\u0130lgili Ba\u011flant\u0131lar<\/h2>\n<p>Ana Kart Y\u00f6netim Denetleyicileri hakk\u0131nda daha fazla bilgi i\u00e7in a\u015fa\u011f\u0131daki kaynaklara bak\u0131n:<\/p>\n<ul>\n<li><a href=\"https:\/\/www.intel.com\/content\/www\/us\/en\/servers\/ipmi\/ipmi-home.html\" target=\"_new\" rel=\"noopener nofollow\">Ak\u0131ll\u0131 Platform Y\u00f6netim Aray\u00fcz\u00fc (IPMI) Spesifikasyonu<\/a><\/li>\n<li><a href=\"https:\/\/topics-cdn.dell.com\/pdf\/idrac9-lifecycle-controller-v4.30.30.30_users-guide3_en-us.pdf\" target=\"_new\" rel=\"noopener nofollow\">Dell EMC OpenManage BMC Kullan\u0131c\u0131 K\u0131lavuzu<\/a><\/li>\n<li><a href=\"https:\/\/www.supermicro.com\/manuals\/other\/BMC_WEB_UI_UserGuide.pdf\" target=\"_new\" rel=\"noopener nofollow\">Supermicro Anakart Y\u00f6netim Denetleyicisi Kullan\u0131c\u0131 K\u0131lavuzu<\/a><\/li>\n<\/ul>\n<p>Sonu\u00e7 olarak, Temel Kart Y\u00f6netim Denetleyicileri, modern sunucu sistemlerinin temel bile\u015fenleridir ve kritik uzaktan y\u00f6netim ve izleme yetenekleri sa\u011flar. Teknoloji ilerlemeye devam ettik\u00e7e BMC, \u00e7e\u015fitli sekt\u00f6rlerdeki sunucu altyap\u0131lar\u0131n\u0131n istikrar\u0131n\u0131, g\u00fcvenilirli\u011fini ve verimlili\u011fini sa\u011flamada daha da \u00f6nemli bir rol oynamaya haz\u0131rlan\u0131yor. OneProxy gibi proxy sunucu sa\u011flay\u0131c\u0131lar\u0131, operasyonlar\u0131n\u0131 kolayla\u015ft\u0131rmak ve m\u00fc\u015fterilerine daha iyi hizmetler sunmak i\u00e7in BMC&#039;nin g\u00fcc\u00fcnden yararlanabilir.<\/p>","protected":false},"featured_media":475984,"menu_order":0,"template":"","meta":{"_acf_changed":false,"content-type":"","inline_featured_image":false,"footnotes":""},"class_list":["post-475983","wiki","type-wiki","status-publish","has-post-thumbnail","hentry"],"acf":{"faq_title":"Frequently Asked Questions about <mark>Baseboard Management Controller (BMC): A Comprehensive Overview<\/mark>","faq_items":[{"question":"What is a Baseboard Management Controller (BMC)?","answer":"<p>A Baseboard Management Controller (BMC) is a critical component in modern computer systems, responsible for managing hardware and monitoring system health. It operates independently of the main CPU and has its dedicated processor, memory, and network interface.<\/p>"},{"question":"How does a Baseboard Management Controller work?","answer":"<p>The BMC runs specialized firmware on its microcontroller or low-power CPU. It constantly monitors system health through sensors, maintains a system event log, and provides remote console access via various communication channels like Intelligent Platform Management Bus (IPMB) or Serial over LAN (SOL).<\/p>"},{"question":"What are the key features of a Baseboard Management Controller?","answer":"<p>The BMC offers remote power control, alerting and monitoring capabilities, system recovery options, BIOS management, and support for virtual media. These features enable administrators to manage and troubleshoot servers from anywhere with internet connectivity.<\/p>"},{"question":"What are the types of Baseboard Management Controllers?","answer":"<p>There are four main types of BMC solutions: Dedicated BMC (standalone integrated into the server hardware), Integrated BMC (integrated into the mainboard), SoC BMC (integrated into the server's System-on-Chip), and External BMC (a separate appliance connected via USB or LAN).<\/p>"},{"question":"How can Baseboard Management Controllers be used?","answer":"<p>BMCs are used for remote server management, troubleshooting, diagnostics, and power optimization. They enable administrators to efficiently handle server infrastructure and promptly address issues.<\/p>"},{"question":"What are the future perspectives of Baseboard Management Controllers?","answer":"<p>The future of BMC lies in improved security, broader integration with cloud-based management platforms, and advanced predictive analytics for proactive system management.<\/p>"},{"question":"How can proxy server providers benefit from Baseboard Management Controllers?","answer":"<p>Proxy server providers like OneProxy can use BMC for efficient monitoring and control of their server infrastructure. BMC helps reduce downtime, address issues promptly, and optimize power consumption for better service delivery.<\/p>"},{"question":"Where can I find more information about Baseboard Management Controllers?","answer":"<p>For more information on Baseboard Management Controllers, refer to these resources:<\/p><ul><li><a href=\"https:\/\/www.intel.com\/content\/www\/us\/en\/servers\/ipmi\/ipmi-home.html\" target=\"_new\">Intelligent Platform Management Interface (IPMI) Specification<\/a><\/li><li><a href=\"https:\/\/topics-cdn.dell.com\/pdf\/idrac9-lifecycle-controller-v4.30.30.30_users-guide3_en-us.pdf\" target=\"_new\">Dell EMC OpenManage BMC User's Guide<\/a><\/li><li><a href=\"https:\/\/www.supermicro.com\/manuals\/other\/BMC_WEB_UI_UserGuide.pdf\" target=\"_new\">Supermicro Baseboard Management Controller User's Guide<\/a><\/li><\/ul>"}]},"_links":{"self":[{"href":"https:\/\/oneproxy.pro\/tr\/wp-json\/wp\/v2\/wiki\/475983","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/oneproxy.pro\/tr\/wp-json\/wp\/v2\/wiki"}],"about":[{"href":"https:\/\/oneproxy.pro\/tr\/wp-json\/wp\/v2\/types\/wiki"}],"version-history":[{"count":0,"href":"https:\/\/oneproxy.pro\/tr\/wp-json\/wp\/v2\/wiki\/475983\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/oneproxy.pro\/tr\/wp-json\/wp\/v2\/media\/475984"}],"wp:attachment":[{"href":"https:\/\/oneproxy.pro\/tr\/wp-json\/wp\/v2\/media?parent=475983"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}